Difference between revisions of "Lecture 3."

From Maxwell
Jump to: navigation, search
(Magnetic Vector Potential)
 
(35 intermediate revisions by the same user not shown)
Line 6: Line 6:
 
| width=50% |
 
| width=50% |
 
'''Instructor'''
 
'''Instructor'''
* Dániel Marcsa (lecturer)
+
* [http://wiki.maxwell.sze.hu/index.php/Marcsa Dániel Marcsa] (lecturer)
 
* Lectures: Monday, 14:50 - 16:25 (D201), 16:30 - 17:15 (D105)
 
* Lectures: Monday, 14:50 - 16:25 (D201), 16:30 - 17:15 (D105)
 
* Office hours: by request
 
* Office hours: by request
Line 15: Line 15:
 
|}
 
|}
  
== Csatolt végeselem-módszer (FEM) ==
+
== Coupled Finite Element Method<ref>[https://www.springer.com/gp/book/9783642090516 M. Kaltenbacher - Numerical Simulation of Mechatronic Sensors and Actuators, Springer-Verlag Berlin Heidelberg, 2007.]</ref> ==
 +
<blockquote>
 +
=== Rigid Body Motion<ref>[http://maxwell.sze.hu/~marcsa/docs/Daniel-MarcsaBScThesis.pdf D. Marcsa - Induction Motors Simulation by Finite Element Method and Different Potential Formulations with Motion Voltage Term, B.Sc. Thesis, University of Győr, 2008.]</ref> ===
 +
In electromechanical systems (electric machines, actuators, etc.), the structure is subject to a rigid motion by means of the force and torque. Thus, the change on the geometry, in turn, may strongly influence the magnetic field. Further, due to the motion and time-varying magnetic field, eddy currents are generated in the conducting parts (where <math>\sigma\neq 0</math>). The so-called induced current (eddy current) in an electrically conductive body
  
<blockquote>
+
::<math>\vec{J}_{M} = \sigma\vec{v}\times\vec{B}</math>,
 +
 
 +
where <math>\vec{v}</math> is the velocity of the body.
 +
 
 +
=== Electric Circuit Coupling ===
 +
In most of the cases, the system is voltage fed and the current in the coil is an unknown. To solve this problem, both the field equations and the electric circuit equations must be solved simultaneously. The circuit equation for a coil can be written as
 +
 
 +
::<math>u(t) = R i(t) + N\frac{\text{d}\Phi(t)}{\text{d}t}</math>,
 +
 
 +
where <math>u(t)</math> is the voltage on the coil, <math>R</math> and <math>N</math> are the coil resistance and the number of turns, <math>\Phi(t)</math> is the magnetic flux [Wb/m] generated in the solution domain and linked by the coil.
 +
 
 +
Finally, the matrix equation of strongly coupled problem is
  
 +
::<math>\begin{bmatrix}
 +
\mathbf{S}+\frac{\mathbf{N}}{\Delta t} & -\mathbf{P} \\
 +
\frac{\mathbf{Q}}{\Delta t} & \mathbf{R}
 +
\end{bmatrix}\begin{bmatrix}
 +
\mathbf{A}(t)\\
 +
\mathbf{I}(t)
 +
\end{bmatrix} = \begin{bmatrix}
 +
\frac{\mathbf{N}}{\Delta t} & \mathbf{0} \\
 +
\frac{\mathbf{Q}}{\Delta t} & \mathbf{0}
 +
\end{bmatrix}\begin{bmatrix}
 +
\mathbf{A}(t-\Delta t)\\
 +
\mathbf{I}(t-\Delta t)
 +
\end{bmatrix}+\begin{bmatrix}
 +
\mathbf{0}\\
 +
\mathbf{U}(t)
 +
\end{bmatrix}</math>
  
 +
where <math>\mathbf{A}</math> is the vector of unknown magnetic vector potential, <math>\mathbf{I}</math> is the vector of unknown coil currents and <math>\mathbf{U}</math> is the vector of voltage sources. <math>\mathbf{S}</math> is the matrix related to <math>\mu</math> permeability, <math>\mathbf{N}</math> is the matrix related to <math>\sigma</math> conductivity. <math>\mathbf{P}</math> is the matrix related to the current in coil and <math>\mathbf{Q}</math> is the matrix related to the coil flux linkage. <math>\mathbf{R}</math> is the diagonal matrix of coils DC resistance and <math>\mathbf{U}</math> is the vector of voltage sources.
 
</blockquote>
 
</blockquote>
  
== Quasistatic Electromagnetic Field ==
+
== Time-Dependent Magnetic Field<ref>[http://maxwell.sze.hu/docs/C4.pdf M. Kuczmann - Potential Formulations in Magnetics Applying the Finite Element Method, Lecture Note, University of Győr, 2009.]</ref> ==
 
<blockquote>
 
<blockquote>
The most important case for electromagnetic equipment (sensors, actuators, motors, etc.) is the quasistatic case often referred to as the eddy current or magnetodynamic case. For quasistatic electromagnetic field we can neglect the displacement current density term <math>\partial \vec{D}/\partial t</math>, which gives Maxwell's equations to the following form
+
The most important case for electromagnetic equipment (sensors, actuators, motors, etc.) is the quasistatic case often referred to as the eddy current or magnetodynamic case. For quasistatic electromagnetic field, we can neglect the displacement current density term <math>\partial \vec{D}/\partial t</math>, which gives Maxwell's equations to the following form
  
 
{| width=60%,
 
{| width=60%,
Line 44: Line 75:
 
|}
 
|}
  
=== Magnetic Vector Potential ===
+
=== Magnetic Vector Potential and Electric Scalar Potential===
 
According to <math>\nabla\cdot\vec{B}(\vec{r},t)=0</math> the magnetic flux density is conservative and therefore can be described by the '''curl''' of a vector
 
According to <math>\nabla\cdot\vec{B}(\vec{r},t)=0</math> the magnetic flux density is conservative and therefore can be described by the '''curl''' of a vector
  
<math> \vec{B} = \nabla\times\vec{A}</math>,
+
::<math> \vec{B} = \nabla\times\vec{A}</math>,
  
 
where <math>\vec{A}</math> is the magnetic vector potential [Wb/m]. Substituting this expression into Faraday's law results in
 
where <math>\vec{A}</math> is the magnetic vector potential [Wb/m]. Substituting this expression into Faraday's law results in
  
<math>\nabla\times\vec{E}=-\frac{\partial}{\partial t} \left(\nabla\times\vec{A}\right)=-\nabla\times\lft(\frac{\partial\vec{A}}{\partial t}\right) \to \nabla\times\left(\vec{E}+\frac{\partial\vec{A}}{\partial t}\right)=\vec{0}</math>,
+
::<math>\nabla\times\vec{E}=-\frac{\partial}{\partial t} \left(\nabla\times\vec{A}\right)=-\nabla\times\left(\frac{\partial\vec{A}}{\partial t}\right) \to \nabla\times\left(\vec{E}+\frac{\partial\vec{A}}{\partial t}\right)=\vec{0}</math>,
  
 
because rotation (i.e. derivative by space) and derivation by time can be replaced. The curl-less vector field <math>\vec{E}+\partial\vec{A}/\partial t</math> can be derived from the so-called electric scalar potential <math>V</math> (<math>\nabla\times\nabla\varphi\equiv0</math>, for any scalar function <math>\varphi=\varphi(\vec{r})</math>, or <math>\varphi=\varphi(\vec{r},t)</math>),
 
because rotation (i.e. derivative by space) and derivation by time can be replaced. The curl-less vector field <math>\vec{E}+\partial\vec{A}/\partial t</math> can be derived from the so-called electric scalar potential <math>V</math> (<math>\nabla\times\nabla\varphi\equiv0</math>, for any scalar function <math>\varphi=\varphi(\vec{r})</math>, or <math>\varphi=\varphi(\vec{r},t)</math>),
  
<math>\vec{E}+\frac{\partial\vec{A}}{\partial t}=-\nabla V</math>,
+
::<math>\vec{E}+\frac{\partial\vec{A}}{\partial t}=-\nabla V</math>,
  
 
and the <math>\vec{E}</math> electric field intensity vector can be described by two potentials as
 
and the <math>\vec{E}</math> electric field intensity vector can be described by two potentials as
  
<math>\vec{E}=-\frac{\partial\vec{A}}{\partial t}-\nabla V</math>.
+
::<math>\vec{E}=-\frac{\partial\vec{A}}{\partial t}-\nabla V</math>.
 +
 
 +
Substituting expression of <math>\vec{B}</math> and <math>\vec{E}</math> into Faraday's law leads to the partial differential equation
 +
 
 +
::<math>\nabla\times\left(\frac{1}{\mu}\nabla\times\vec{A}\right)=\vec{J}_{S}-\sigma\frac{\partial\vec{A}}{\partial t}-\sigma\nabla V+\sigma\vec{v}\times\nabla\times\vec{A}</math>.
  
 +
If the velocity is a priori known, the additional term remains linear but will lead to a so-called convective term. Therefore, numerical computation will need some upwind technique for stability reasons.
 
</blockquote>
 
</blockquote>
  
== Irodalom ==
+
== References ==
 
{{reflist}}
 
{{reflist}}

Latest revision as of 19:52, 28 January 2020

Coupled Finite Element Method / Time-Dependent Magnetic Field

Instructor

  • Dániel Marcsa (lecturer)
  • Lectures: Monday, 14:50 - 16:25 (D201), 16:30 - 17:15 (D105)
  • Office hours: by request

Teaching Assistants:

  • -
  • Office hours: -.

Coupled Finite Element Method[1]

Rigid Body Motion[2]

In electromechanical systems (electric machines, actuators, etc.), the structure is subject to a rigid motion by means of the force and torque. Thus, the change on the geometry, in turn, may strongly influence the magnetic field. Further, due to the motion and time-varying magnetic field, eddy currents are generated in the conducting parts (where [math]\sigma\neq 0[/math]). The so-called induced current (eddy current) in an electrically conductive body

[math]\vec{J}_{M} = \sigma\vec{v}\times\vec{B}[/math],

where [math]\vec{v}[/math] is the velocity of the body.

Electric Circuit Coupling

In most of the cases, the system is voltage fed and the current in the coil is an unknown. To solve this problem, both the field equations and the electric circuit equations must be solved simultaneously. The circuit equation for a coil can be written as

[math]u(t) = R i(t) + N\frac{\text{d}\Phi(t)}{\text{d}t}[/math],

where [math]u(t)[/math] is the voltage on the coil, [math]R[/math] and [math]N[/math] are the coil resistance and the number of turns, [math]\Phi(t)[/math] is the magnetic flux [Wb/m] generated in the solution domain and linked by the coil.

Finally, the matrix equation of strongly coupled problem is

[math]\begin{bmatrix} \mathbf{S}+\frac{\mathbf{N}}{\Delta t} & -\mathbf{P} \\ \frac{\mathbf{Q}}{\Delta t} & \mathbf{R} \end{bmatrix}\begin{bmatrix} \mathbf{A}(t)\\ \mathbf{I}(t) \end{bmatrix} = \begin{bmatrix} \frac{\mathbf{N}}{\Delta t} & \mathbf{0} \\ \frac{\mathbf{Q}}{\Delta t} & \mathbf{0} \end{bmatrix}\begin{bmatrix} \mathbf{A}(t-\Delta t)\\ \mathbf{I}(t-\Delta t) \end{bmatrix}+\begin{bmatrix} \mathbf{0}\\ \mathbf{U}(t) \end{bmatrix}[/math]

where [math]\mathbf{A}[/math] is the vector of unknown magnetic vector potential, [math]\mathbf{I}[/math] is the vector of unknown coil currents and [math]\mathbf{U}[/math] is the vector of voltage sources. [math]\mathbf{S}[/math] is the matrix related to [math]\mu[/math] permeability, [math]\mathbf{N}[/math] is the matrix related to [math]\sigma[/math] conductivity. [math]\mathbf{P}[/math] is the matrix related to the current in coil and [math]\mathbf{Q}[/math] is the matrix related to the coil flux linkage. [math]\mathbf{R}[/math] is the diagonal matrix of coils DC resistance and [math]\mathbf{U}[/math] is the vector of voltage sources.

Time-Dependent Magnetic Field[3]

The most important case for electromagnetic equipment (sensors, actuators, motors, etc.) is the quasistatic case often referred to as the eddy current or magnetodynamic case. For quasistatic electromagnetic field, we can neglect the displacement current density term [math]\partial \vec{D}/\partial t[/math], which gives Maxwell's equations to the following form

[math]\nabla\times\vec{H}=\vec{J}[/math]

          Ampere's law,

[math]\nabla\times\vec{E}=-\frac{\partial \vec{B}}{\partial t}[/math]

          Faraday's law,

[math]\nabla\cdot\vec{B}(\vec{r},t)=0[/math]

          Gauss's law (magnetic).

Magnetic Vector Potential and Electric Scalar Potential

According to [math]\nabla\cdot\vec{B}(\vec{r},t)=0[/math] the magnetic flux density is conservative and therefore can be described by the curl of a vector

[math] \vec{B} = \nabla\times\vec{A}[/math],

where [math]\vec{A}[/math] is the magnetic vector potential [Wb/m]. Substituting this expression into Faraday's law results in

[math]\nabla\times\vec{E}=-\frac{\partial}{\partial t} \left(\nabla\times\vec{A}\right)=-\nabla\times\left(\frac{\partial\vec{A}}{\partial t}\right) \to \nabla\times\left(\vec{E}+\frac{\partial\vec{A}}{\partial t}\right)=\vec{0}[/math],

because rotation (i.e. derivative by space) and derivation by time can be replaced. The curl-less vector field [math]\vec{E}+\partial\vec{A}/\partial t[/math] can be derived from the so-called electric scalar potential [math]V[/math] ([math]\nabla\times\nabla\varphi\equiv0[/math], for any scalar function [math]\varphi=\varphi(\vec{r})[/math], or [math]\varphi=\varphi(\vec{r},t)[/math]),

[math]\vec{E}+\frac{\partial\vec{A}}{\partial t}=-\nabla V[/math],

and the [math]\vec{E}[/math] electric field intensity vector can be described by two potentials as

[math]\vec{E}=-\frac{\partial\vec{A}}{\partial t}-\nabla V[/math].

Substituting expression of [math]\vec{B}[/math] and [math]\vec{E}[/math] into Faraday's law leads to the partial differential equation

[math]\nabla\times\left(\frac{1}{\mu}\nabla\times\vec{A}\right)=\vec{J}_{S}-\sigma\frac{\partial\vec{A}}{\partial t}-\sigma\nabla V+\sigma\vec{v}\times\nabla\times\vec{A}[/math].

If the velocity is a priori known, the additional term remains linear but will lead to a so-called convective term. Therefore, numerical computation will need some upwind technique for stability reasons.

References

  1. M. Kaltenbacher - Numerical Simulation of Mechatronic Sensors and Actuators, Springer-Verlag Berlin Heidelberg, 2007.
  2. D. Marcsa - Induction Motors Simulation by Finite Element Method and Different Potential Formulations with Motion Voltage Term, B.Sc. Thesis, University of Győr, 2008.
  3. M. Kuczmann - Potential Formulations in Magnetics Applying the Finite Element Method, Lecture Note, University of Győr, 2009.